|
caledonian
Products >> 300/500V Mica+XLPE Insulated & Lszh Sheathed Fire Alarm Cables
Build Your Online Product Catalogs?
Product Name: |
300/500V Mica+XLPE Insulated & Lszh Sheathed Fire Alarm Cables
|
Supply Ability: |
|
Related proudcts |
300/500v mica+xlpe i, |
Specifications |
300/500V Mica+XLPE I |
Price Term: |
|
Port of loading: |
|
Minimum Order |
|
Unit Price: |
|
|
Model NO.: Fire Resistant LSOH Sheathed Cables Type: Insulated Conductor Type: Stranded Conductor Material: Copper Sheath Material: Lszh Insulation Material: XLPE Material Shape: Round Wire Range of Application: Flame Retardant Certification: ISO9001, CE, UL, CCC, RoHS, VDE Brand: Caledonian Export Markets: Global Product Description
APPLICATION The cables are designed, manufactured and tested as data transmission cables for emergency services. These are primarily intended for for indoor instrumentation and control cabling, electrically noisy environments and fire alarm systems in office buildings when high frequency signal transmission has to be assured in the event of a fire. STANDARDS Basic design to BS 7629-1 FIRE PERFORMANCE
Circuit Integrity IEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180); CEI 20-36/2-1; SS299-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1) System circuit integrity DIN 4102-12, E30 depending on lay system Flame Retardance (Single Vertical Wire Test) EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* Reduced Fire Propagation (Vertically-mounted bundled wires & cable test) EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1);CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 Halogen Free IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1; BS 6425-1* No Corrosive Gas Emission IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2; BS 6425-2* Minimum Smoke Emission IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* No Toxic gases NES 02-713; NF C 20-454
Note: Asterisk * denotes superseded standard CABLE CONSTRUCTION
Conductor Plain annealed copper wire, stranded according to IEC 60228 class 2 Insulation Mica glass tape covered by extruded XLPE compound or cross-linked compound type EI5 as per BS 7655: section 5.1 Cabling Elemen |
Company: |
caledonian
|
Contact: |
Ms. winni winni |
Address: |
Room3501, Citic Square, 1168, Nanjing Xi Lu, 200041, Shanghai, China |
Postcode: |
|
Tel: |
18930597072 |
Fax: |
86-21-52524616 |
E-mail: |
|
|
|
|