|
caledonian
Products >> 225V Sr Insulated & Lszh Sheathed Fire Alarm Cables

Build Your Online Product Catalogs?
Product Name: |
225V Sr Insulated & Lszh Sheathed Fire Alarm Cables
|
Supply Ability: |
|
Related proudcts |
|
Specifications |
225V Sr Insulated & Lszh Sheathed Fire Alarm Cables |
Price Term: |
|
Port of loading: |
|
Minimum Order |
|
Unit Price: |
|
|
Model NO.: Fire Resistant LSOH Sheathed Cables Type: Insulated Conductor Type: Stranded Conductor Material: Copper Sheath Material: Lszh Insulation Material: XLPE Material Shape: Round Wire Range of Application: Flame Retardant Certification: ISO9001, CE, UL, CCC, RoHS, VDE Brand: Caledonian Export Markets: Global Product Description
APPLICATION The cables are used for the internal wiring of building when the circuit integrity during fire is paramount. The cables are intended for use in fire fighting plants with special ceramized silicone insulation, with and without aluminum foil and LSZH outer sheath. The fire alarm cables with 30 to 90 minutes circuit integrity should be used for control voltages and data transfer in alarm and fire alarm systems, where a system circuit integrity E30/E60/E90 depending on lay system in accordance with DIN 4102-12 is required. The circuit integrity is guaranteed with a test voltage of 110V. STANDARDS Basic design to VDE 0815 FIRE PERFORMANCE
Circuit Integrity IEC 60331-23; BS 6387 CWZ; DIN VDE 0472-814(FE180); CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1) System circuit integrity DIN 4102-12, E30 depending on lay system Flame Retardance (Single Vertical Wire Test) EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2);CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* Reduced Fire Propagation (Vertically-mounted bundled wires & cable test) EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 Halogen Free IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1; BS 6425-1* No Corrosive Gas Emission IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2; BS 6425-2* Minimum Smoke Emission IEC 61034-1&2; EN 61034-1&2; DIN VDE 0482-1034-1&2;CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* No Toxic gases NES 02-713; NF C 20-454
Note: Asterisk * denotes superseded stand |
Company: |
caledonian
|
Contact: |
Ms. winni winni |
Address: |
Room3501, Citic Square, 1168, Nanjing Xi Lu, 200041, Shanghai, China |
Postcode: |
|
Tel: |
18930597072 |
Fax: |
86-21-52524616 |
E-mail: |
|
|
|
|